Prepared For:
Morry Modestmeans
Property Address:
123 Stylish Condo Drive
Fashionville, IL
_______________________________________________________
William J. Decker Jr. Illinois State License 050.0002240
| Date: 1/2/2004 | Time: 3:20 PM | Report ID: Exp 2 Condo |
| Property: 123 Stylish Condo Drive Fashionville, IL |
Customer: Morry Modestmeans |
Real Estate
Professional: |
The subject property is a 'Garden Apartment' condominium situated in a multiple unit apartment condominium conversion. The building was built in 1917 and has been rather extensively renovated. The subject property is the garden (below ground level) on the north side of the west facing common courtyard, 2nd in from the street. The rear entrance of the subject property (Picture 2) is located on the north side of the structure, on the alley.
The subject unit has a step down entryway that leads to the living room area, a small kitchen area to the north of the living room, two bedrooms, located on the north and south sides of the eastern portion of the unit and a single bathroom, located on the north wall between the north bedroom and the kitchen.
The structure was built in 1925, according to public tax records and contains approximately 23 separate units.
This condominium inspection is a partial inspection and is performed on only those components that the buyer or homeowner is responsible for. It does not include inspection of the exterior components of the property, common areas, crawlspace, basement or attic and all of the components contained therein except as in a general overview and as accessible at the time of the inspection as these systems, components and items are usually owned, in common, by the association and is not owned by the buyer or home owner. It is up to the buyer to determine if any of these excluded areas are in fact within the scope of the real estate transaction and are the buyers responsibility and, if so, to notify the inspector so these particular areas will be inspected.
Please Note: A different charge will apply should the buyer want these areas inspected. It also is not possible in some cases to inspect attic areas where a duplex unit exist and the buyer is purchasing the lower unit, or vice versa. Our company makes no representation as to the condition of these areas that were not inspected.
Comment Key or Definitions
The following definitions of comment descriptions represent this
inspection report. All comments by the inspector should be read and
considered when evaluating this property.
Note:Any recommendations by the inspector
to repair or replace or deal with a significantly
deficient item suggests an evaluation by a licensed
and insured contractor specifically qualified to determine the
condition and safety of the described item, component or system. Please
note that Home Inspectors in the State of Illinois are required to note any
safety hazards, whether they comply with older, obsolete local building codes
or not. Licensed and insured contractors are not. Repairs done
by persons other that licensed and insured contractors carry with them added
liability for the customer. All work
done on the subject property should be accompanied by a copy of all invoices and
warranties, such warranties should be transferable to the new owner and should
include the contractor's license number and a copy of their insurance
certification.
Category Definitions:
Inspected (IN) = The system, component or item was visually observed at a certain time and under certain conditions.Not Inspected (NI)= The system, component or item was not inspected and no representations of whether or not it was functioning are intended. The reason could be that the item was not connected (gas, water, electrical disconnected), obstructed, or not accessible. In any case, the reason that the item, system or component was not inspected is stated in the comments.
Not Present (NP) = This system, component or item is not present in the subject property.
Watch List or Maintenance (WL) =Either the system, component or item needs regular maintenance to remain functioning in a proper manner and those maintenance processes are noted or the item should be watched in anticipation of future problems.Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a licensed and insured contractor. Most of these type of comments describe items that will lead to more serious problems if not addressed. Items, components or systems that can be repaired to satisfactory condition may not need replacement.
Significantly Deficient (SD) = Defined by Illinois State Law as either a) not functioning or b) posing a safety hazard. It should be noted that a large number of significantly deficient items can be addressed at little cost. It is important to remember that The safety of a significantly deficient item is not based upon mere local building codes, which contain 'grandfathering' clauses, or the common practices of tradesmen, but on national and international safety requirements and with the well being of the property and the client in mind.
Please Note: If you have any questions or any thing is unclear, please do not hesitate to contact Decker Home Services and/or your specific inspector. We are happy to answer any of your questions and have a large knowledge base of information and experienced, qualified expert NACHI instructors and inspectors from around the entire country at our disposal. We consider it very important for you to fully and completely understand the condition of the subject property and will do all we can to help you in the process.
| Age Of Home: Over 50 Years (1925) |
Client Is
Present: Yes |
Realtors Present: Seller's Realtor |
| Weather: Clear |
Temperature: 92 |
Rain in last 3
days: No |
| Radon Test: No |
Mold Test: No |
Water Test: No |
9356 N. Keeler Skokie, IL 60076 H: (847) 673-2702 C: (847) 609-2345 |
|
Customer |
|
Property Address |
| 1.1 | FOUNDATION - Findings | |
| Inspected, Watch List - Maintenance | ||
|
Recommend, as part of general considerations
for the owner's association, that the portion of the foundation facing the
street be packed with packing rod and caulked with an appropriate mortar
caulk, to guard against water infiltration into the basement
areas, by a licensed and insured masonry
contractor. | ||
| 2.3 | WINDOWS (Exterior) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the junction of the
window metal cladding and the exterior brick be caulked to prevent water
penetration.
2) RR - Recommend that the security bar frame that covers the subject properties north bedroom window be secured with concrete screws to the exterior wall. | ||
| 4.2 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the metal cover for the
bathtub water supply handle be replaced to avoid water infiltration into
the wall behind the valve. | ||
| 5.2 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS - Findings | |
| Inspected, Repair or Replace, Significantly Deficent | ||
|
1) SD - The main electrical disconnects in the
common basement utility room are not labeled and seem to control multiple
units in the building. This is a safety hazard because it is not
known which disconnect switch serves the subject unit. Likewise,
none of the individual circuit breakers for the subject units branch
circuits are labeled. This is also a safety hazard. It is also
the opinion of this inspector that the accessibility of both the main
electrical disconnect and the subject units circuit breakers is a safety
hazard, but may be in accordance with local building codes.
2) RR - Recommend that the wire serving the 20 amp breaker, 2nd from the top, be evaluated by a licensed and insured electrical contractor. It appears to be under sized (14 gauge, not the required 12 gauge) for the breaker. | ||
| 5.5 | CONNECTED DEVICES AND FIXTURES - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the loose receptacle
located on the south bedroom be secured by a licensed and insured
electrician. Recommend that the voltage drop condition in the
outlets, especially demonstrated in the living room, southwest corner and
in the north bedroom, be evaluated by a licensed and insured
electrician. The voltage drop on these outlets exceeded 5% under a
12 amp load. | ||
| 5.7 | GFCI, AFCI PROTECTION OF RECEPTACLES - Findings | |
| Inspected, Significantly Deficent | ||
|
1) SD - Recommend that the kitchen countertop
outlet, located to the right of the kitchen sink on the east wall be GFCI
protected and that the work be done by a licensed and insured electrical
contractor.
2) SD - Recommend that bedroom outlets and lights be AFCI protected. | ||
| 5.9 | SMOKE DETECTORS, CARBON MONOXIDE DETECTORS - Findings | |
| Inspected, Significantly Deficent | ||
|
Recommend that smoke detectors be located in
the hallways outside of bedrooms, at the top and bottom of all multiple
floor stairways and in the kitchen ceiling.
Recommend that all bedrooms be equipped with carbon monoxide detectors and that a carbon monoxide detector be located in any utility areas containing a fuel burning furnace and./or water heater. It is recommended that all smoke and carbon monoxide detectors be hard wired to the properties main electrical system and that they also be equipped with battery backup. Recommend that smoke detectors be located in the hallways outside of bedrooms, at the top and bottom of all multiple floor stairways and in the kitchen ceiling. Recommend that all bedrooms be equipped with carbon monoxide detectors and that a carbon monoxide detector be located in any utility areas containing a fuel burning furnace and./or water heater. It is recommended that all smoke and carbon monoxide detectors be hard wired to the properties main electrical system and that they also be equipped with battery backup. | ||
| 6.1 | HEATING EQUIPMENT - Findings | |
| Inspected, Watch List - Maintenance, Significantly Deficent | ||
|
1) SD - Recommend that the furnace be
evaluated by a licensed and insured HVAC contractor to determine if the
amount of combustion air is sufficient for proper furnace operation.
This is a safety concern. Further recommend that the operation of
the two leftmost furnace burners, which did not light properly during a
heat cycle, also be evaluated at this time.
2) WL - Recommend that the furnace be inspected and maintained annually as a part of a regular maintenance schedule. | ||
| 6.5 | HEAT DISTRIBUTION SYSTEMS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the sufficiency of the
return duct system, especially with regards to the seeming lack of a
proper supply of combustion air, be evaluated by a licensed and insured
HVAC contractor. | ||
| 8.2 | WALLS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the wall trim
baseboards, located at the base of the front entry stair railing supports
be installed by a licensed and insured trim carpenter.
2) RR - Recommend that, at least, the crack on the corner of the tub surround tile shelf be re-grouted. A better and more lasting solution would be to remove the tile from this area, install the proper concrete type wall board and reset the tile. The tun surround should also have its grout sealed with a silicone grout sealer. Recommend that this area be evaluated by a licensed and insured tiling contractor for repair | ||
| 8.4 | FLOORS - Findings | |
| Inspected, Watch List - Maintenance, Repair or Replace | ||
|
1) WL - Recommend that the grout in the tile
floor be sealed with a silicone sealant to guard against water
infiltration to the floor below.
2) RR - Recommend that the places where different floor types (laminate wooden flooring and tile) be equipped with thresholds boards to conceal the underlying floor. Recommend that the threshold be a flat type so as to minimize any trip hazard. Since the underlying floor is a concrete slab, recommend that the threshold be installed with the proper type concrete screws. | ||
Prepared Using HomeGauge http://www.homegauge.com/ SHGI (c)
2000-2004 : Licensed To Decker Home Services, LLC.
| FOUNDATION: POURED CONCRETE |
FRAMING METHOD: Brick Sturcture |
FLOOR STRUCTURE: 2 X 10 WOOD JOISTS |
| WALL STRUCTURE: BRICK |
BEAMS COLUMNS OR
PIERS: STEEL GIRDER STEEL COLUMNS |
CEILING STRUCTURE: FLOOR JOISTS COMMON TO CEILING JOISTS |
| ROOF STRUCTURE: NOT VISIBLE |
ROOF-TYPE: FLAT |
ATTIC ACCESS: NO ATTIC |
| METHOD USED TO OBSERVE
ATTIC: NO ATTIC |
CRAWLSPACE ACCESS: NO CRAWLSPACE |
METHOD USED TO OBSERVE
CRAWLSPACE: NO CRAWLSPACE |
| 1.0 | FOUNDATION - Inspect and
Describe Comments: Inspected The foundation of the structure is older poured concrete. It was inspected from the exterior and found to be without major signs of cracking, spalling or major deterioration. The street facing portion of the foundation, where the foundation met the street, displayed areas where there was seperation from the adjacent sidewalk and signs of less than professional attempts to guard against water infiltration by applying mortar along the foundation / sidewalk interface (Picture 1). These patching attempts display cracking and peeling away of the mortar. The side of this structure closest to the subject property unit displays only minor signs of cracking or damage (Picture 2)consistent with the age of the structure.
|
| 1.1 | FOUNDATION -
Findings Comments: Inspected, Watch List - Maintenance Recommend, as part of general considerations for the owner's association, that the portion of the foundation facing the street be packed with packing rod and caulked with an appropriate mortar caulk, to guard against water infiltration into the basement areas, by a licensed and insured masonry contractor. |
| 1.2 | WALLS - Inspect and
Describe Comments: Inspected Structure walls are brick and in generally good condition, exhibiting minor efflorescence (white flack) at the rear north face and minor cracking and spalling at the base (Picture 1).
|
| 1.3 | BEAMS, COLUMNS OR PIERS -
Inspect and Describe Comments: Inspected Structure is equipped with steel girders and steel columns for interior structural support. These girders and their supporting columns display minor signs of rust consistent with their age. |
| 1.4 | FLOORS - Inspect and
Describe Comments: Inspected Floor structure, as observed from that accessible portion of the basement common area. is 2 x 10 wooden joists that are aged, but in generally good condition, exhibiting only minor signs of staining and checking with no signs of rot or excessive moisture content. The floors of the subject unit are concrete slab and were covered with tile and floating laminate flooring. |
| 1.5 | CEILINGS - Inspect and
Describe Comments: Inspected Ceiling structure is common with floor joists of the above units. |
| 1.6 | ROOF STRUCTURE AND ATTIC -
Inspect and Describe Comments: Inspected Roof structure was not able to be observed, but is assumed to be consistent with the 2 x 10 wooden joists of the rest of the structure. |
| SIDING STYLE: BRICK |
SIDING MATERIAL: BRICK VENEER |
EXTERIOR ENTRY DOORS: INSULATED COMPOSITE |
| APPURTENANCE: COMMON COURTYARD SHARED PORCH SLAB UNDER PORCH |
AUTO OPENER
MANUFACTURER: N/A |
GARAGE DOOR MATERIAL: N/A |
| GARAGE DOOR TYPE: N/A |
DRIVEWAY: N/A |
| 2.0 | WALL CLADDING FLASHING AND
TRIM - Inspect and Describe Comments: Inspected Exterior walls are finished brick in the courtyard and facing the street. This brick displays minor signs of mortar crack, consistent with a structure of this are and is probably not indicative of water penetration and has no signs of efflorescence. The remainder of the building is common brick and was recently tuckpointed. There are minor signs of efflorescence at the north west corner as noted in the Structure / Foundation section. |
| 2.1 | DOORS (Exterior) - Inspect
and Describe Comments: Inspected Exterior doors are insulated composite, hang straight and plumb and articulate properly with their latches. |
| 2.2 | WINDOWS (Exterior) - Inspect
and Describe Comments: Inspected Exterior windows are metal clad and display no signs of rust or physical damage. The area where the cladding meets the exterior brick is not caulked (Picture 1) and this may lead to water infiltration, although no interior signs of moisture penetration were seen. The window that serves the north bedroom is equipped with a metal security bar addition. The bar framing is missing securing screws on the left side (Picture 2) and the security bars are loose..
|
| 2.3 | WINDOWS (Exterior) -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the junction of the window metal cladding and the exterior brick be caulked to prevent water penetration. 2) RR - Recommend that the security bar frame that covers the subject properties north bedroom window be secured with concrete screws to the exterior wall. |
| 2.4 | DECKS, BALCONIES, STOOPS,
STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS - Inspect and
Describe Comments: Inspected The rear entrance of the subject property is located under a wooden back porch which serves other units in the building. The porch appears to be in good condition and is properly secured and supported by joists that extend into the building's brick structure and are secured by metal hangers (Picture 1). The ledger board appear to be attached with the proper bolts to anchors on the interior of the brick walls.
|
| ROOF COVERING: BUILT UP |
VIEWED ROOF COVERING
FROM: GROUND |
SKY LIGHT (S): NONE |
| CHIMNEY (exterior): BRICK COMMON CONDOMINIUM CHIMNEY |
| 3.0 | ROOF COVERINGS - Inspect and
Describe Comments: Inspected Roof is flat, built up felt and asphalt type roofing. |
| 3.1 | FLASHINGS, SKYLIGHTS,
CHIMNEYS AND ROOF PENETRATIONS - Inspect and Describe Comments: Inspected Chimney and plumbing vent flashing appears to be proper and without signs of cracking. |
| 3.2 | ROOFING DRAINAGE SYSTEMS -
Inspect and Describe Comments: Inspected Roof is drained by means of gutters, located on the rear of the property and empty into downspouts that drain into below ground drain pipes (Picture 1).
|
| WATER SOURCE: PUBLIC |
WATER FILTERS: NONE |
PLUMBING SUPPLY: NOT VISIBLE |
| PLUMBING
DISTRIBUTION: COPPER |
WASHER DRAIN SIZE: NONE |
PLUMBING WASTE: COPPER |
| WATER HEATER POWER
SOURCE: NOT ACCESSABLE |
CAPACITY: UNKNOWN |
MANUFACTURER: UNKNOWN |
| 4.0 | INTERIOR DRAIN, WASTE AND
VENT SYSTEMS - Inspect and Describe Comments: Inspected All drains emptied properly and the drain vents seem to without clogs. The bathroom tub drains a little slowly, but this is probably because of its below ground positioning. The bathroom tub drain stopper is missing.
Drain pipes and vents are copper. This is a superior installation. |
| 4.1 | INTERIOR WATER SUPPLY AND
DISTRIBUTION SYSTEMS AND FIXTURES - Inspect and Describe Comments: Inspected All fixtures were operated and worked as designed. The one piece shower and tub water control is missing an metal covering that covers the handle shaft (Picture 1). This can lead to leakage of water to the area behind the wall.
|
| 4.2 | INTERIOR WATER SUPPLY AND
DISTRIBUTION SYSTEMS AND FIXTURES - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the metal cover for the bathtub water supply handle be replaced to avoid water infiltration into the wall behind the valve. |
| 4.3 | HOT WATER SYSTEMS, CONTROLS,
CHIMNEYS, FLUES AND VENTS - Inspect and Describe Comments: Inspected Hot water heater is common to multiple units and was not accessible for inspection. Hot water supplied is sufficiently hot. |
| 4.4 | MAIN WATER AND FUEL SHUT-OFF
DEVICES (Describe location) - Findings Comments: Inspected Main waste shut-off was in a common area and was not accessible. Main fuel shut-off is located at the gas meter, located on the south wall of the common utility room area at the northeast corner of the property (Picture 1).
|
| 4.5 | FUEL STORAGE AND DISTRIBUTION
SYSTEMS - Findings Comments: Inspected All fuel supply pipes of at the proper black pipe. Measurement of gas levels along the furnace and cook stove supply lines displayed no signs of leakage. |
| ELECTRICAL SERVICE
CONDUCTORS: OVERHEAD SERVICE 220 VOLTS |
METER CAPACITY: 200 AMPS |
PANEL CAPACITY: 100 AMP |
| PANEL TYPE: CIRCUIT BREAKERS |
ELEC. PANEL
MANUFACTURER: Unknown |
BRANCH WIRE 15 and 20
AMP: COPPER |
| WIRING METHODS: CONDUIT |
| 5.0 | SERVICE DROP AND ENTRANCE,
CONDUCTORS - Inspect and Describe Comments: Inspected The main electrical service drop is overhead and enters the structure at the northeast corner (Picture 1). It appears to be unfrayed and enters the structure by means of rigid pipe to the buildings common utility room, also located at the northeast corner of the structure.
|
| 5.1 | SERVICE AND GROUNDING
EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS - Inspect
and Describe Comments: Inspected The electrical service is controlled by a number of high voltage main disconnect switches located on the east wall at the northeast corner of the common utility area (Picture 1). Each disconnect switch seems to service a number of different units. None of the main disconnect switches are labeled as to what units they serve. The subject units utility meter and circuit breakers are located in the center of the west wall of this common area and labeled as "4409, basement" (Picture 2). The utility meter is rated for 200 amp service and is serving a total of 6 breakers, 2 15 amp, 2 20 amp and a double ganged 20 amp, 240 volt breaker which probably serves the air conditioner compressor unit. Inspection inside the panel displayed no signs of rust or moisture and the wires in the panel were neatly arranged. It appears that the 20 amp breaker, located 2nd from the top (Picture 3), is equipped with 14 gauge wire as opposed to the 12 gauge wire required to carry 20 amps of current. None of the circuit breaker are labeled as to which branch circuits they serve.
|
| 5.2 | SERVICE AND GROUNDING
EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS -
Findings Comments: Inspected, Repair or Replace, Significantly Deficent 1) SD - The main electrical disconnects in the common basement utility room are not labeled and seem to control multiple units in the building. This is a safety hazard because it is not known which disconnect switch serves the subject unit. Likewise, none of the individual circuit breakers for the subject units branch circuits are labeled. This is also a safety hazard. It is also the opinion of this inspector that the accessibility of both the main electrical disconnect and the subject units circuit breakers is a safety hazard, but may be in accordance with local building codes. 2) RR - Recommend that the wire serving the 20 amp breaker, 2nd from the top, be evaluated by a licensed and insured electrical contractor. It appears to be under sized (14 gauge, not the required 12 gauge) for the breaker. |
| 5.3 | BRANCH CIRCUIT CONDUCTORS,
OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE -
Inspect and Describe Comments: Inspected Branch circuit wiring is copper and enclosed in metal conduit. The branch circuit wires display no signs of discoloration or melted insulation. They are all single tapped. As previously noted, one 20 amp breaker is connected to a wire that appears to be undersized (14 gauge wire where a 12 gauge wire is required). |
| 5.4 | CONNECTED DEVICES AND
FIXTURES - Inspect and Describe Comments: Inspected All switches and outlets were tested and operated properly and were found to have proper grounding and polarity. The outlet located on the east wall of the south bedroom was loose in its box (Picture 1). A number of outlets, most notably on the west wall of the living room area and in the north bedroom that tested as having am under load voltage drop that is slightly higher than recommended. The biggest drop was 8.2% at 12 amps where a< 5% voltage drop is recommended.
|
| 5.5 | CONNECTED DEVICES AND
FIXTURES - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the loose receptacle located on the south bedroom be secured by a licensed and insured electrician. Recommend that the voltage drop condition in the outlets, especially demonstrated in the living room, southwest corner and in the north bedroom, be evaluated by a licensed and insured electrician. The voltage drop on these outlets exceeded 5% under a 12 amp load. |
| 5.6 | GFCI, AFCI PROTECTION OF
RECEPTACLES - Inspect and Describe Comments: Inspected The outlets near the kitchen sink and in the bathroom were tested by two methods and operated properly with regard to GFCI protection. There is an outlet located over the kitchen counter top, to the right of the sink (Picture 1) that is not GFCI protected. The bedrooms were not AFCI protected.
|
| 5.7 | GFCI, AFCI PROTECTION OF
RECEPTACLES - Findings Comments: Inspected, Significantly Deficent 1) SD - Recommend that the kitchen countertop outlet, located to the right of the kitchen sink on the east wall be GFCI protected and that the work be done by a licensed and insured electrical contractor. 2) SD - Recommend that bedroom outlets and lights be AFCI protected. |
| 5.8 | SMOKE DETECTORS, CARBON
MONOXIDE DETECTORS - Inspect and Describe Comments: Inspected A smoke detector was located in the hallway, outside the bedrooms and bathroom. No carbon monoxide detectors were noted. |
| 5.9 | SMOKE DETECTORS, CARBON
MONOXIDE DETECTORS - Findings Comments: Inspected, Significantly Deficent Recommend that smoke detectors be located in the hallways outside of bedrooms, at the top and bottom of all multiple floor stairways and in the kitchen ceiling. Recommend that all bedrooms be equipped with carbon monoxide detectors and that a carbon monoxide detector be located in any utility areas containing a fuel burning furnace and./or water heater. It is recommended that all smoke and carbon monoxide detectors be hard wired to the properties main electrical system and that they also be equipped with battery backup. Recommend that smoke detectors be located in the hallways outside of bedrooms, at the top and bottom of all multiple floor stairways and in the kitchen ceiling. Recommend that all bedrooms be equipped with carbon monoxide detectors and that a carbon monoxide detector be located in any utility areas containing a fuel burning furnace and./or water heater. It is recommended that all smoke and carbon monoxide detectors be hard wired to the properties main electrical system and that they also be equipped with battery backup. |
| HEAT TYPE: FORCED AIR |
FURNACE EFFICENCY: FORCED DRAFT INSUFFICIENT COMBUSTION AIR |
ENERGY SOURCE: NATURAL GAS |
| NUMBER OF HEAT SYSTEMS (excluding
fireplaces): ONE |
HEAT SYSTEM BRAND: CARRIER |
DUCTWORK: NON-INSULATED RECTANGULAR GALVANIZED STEEL |
| FILTER TYPE: DISPOSABLE |
TYPES OF FIREPLACES: NONE |
OPERABLE FIREPLACES: NONE |
| NUMBER OF WOODSTOVES: NONE |
| 6.0 | HEATING EQUIPMENT - Inspect
and Describe Comments: Inspected Furnace is a Carrier forced draft unit and was manufactured in 1992. It was located in a small utility closet, located on the west side of the living room area. The door to this utility closet is equipped with two, small vents that appear to have been installed as an afterthought, no doubt in an attempt to to try to increase the amount of combustion air available to the furnace. The furnace is equipped with a standing pilot light flame. The furnace was observed through a heating cycle and operated poorly, with two of the leftmost burners (Picture 1) failing to light promptly. The flame exhibited an overly yellow color which can be consistent with dust buildup or insufficient combustion air. The flame was observed, both with the closet door open and closed and the flame was significantly more yellow with the door closed, indicating that the furnace has an insufficient combustion air supply As is common in apartment building conversion type condominiums, the installation of a separate heating furnace for the subject unit was done without giving proper consideration of the amount of combustion air (air for the heating flame) needed to supply the furnace. The burning of every cubic foot of natural gas requires 10 cubic feet of air to burn properly, completely and safely. Insufficient combustion air can lead to, at least, decreased furnace life and excessive carbon buildup, or at worst, the creation of excessive amounts of carbon monoxide which can lead to death.
|
| 6.1 | HEATING EQUIPMENT -
Findings Comments: Inspected, Watch List - Maintenance, Significantly Deficent 1) SD - Recommend that the furnace be evaluated by a licensed and insured HVAC contractor to determine if the amount of combustion air is sufficient for proper furnace operation. This is a safety concern. Further recommend that the operation of the two leftmost furnace burners, which did not light properly during a heat cycle, also be evaluated at this time. 2) WL - Recommend that the furnace be inspected and maintained annually as a part of a regular maintenance schedule. |
| 6.2 | NORMAL OPERATING AND SAFETY
CONTROLS - Inspect and Describe Comments: Inspected Furnace responded properly to operation of normal operating controls. Both the furnace and the air conditioning unit are controlled by a non setback thermostat located on an interior wall at the center of the west wall of the living room area, near the kitchen area entrance. The blower shut-off switch is located directly to the left of the furnace, on the wall (Picture 1, up arrow). The gas shut-off valve for the furnace is located directly to the left of the furnace (Picture 1, right arrow).
|
| 6.3 | CHIMNEYS, FLUES AND VENTS -
Inspect and Describe Comments: Inspected Furnace is vented to a common chimney by means of round, galvanized steel flue. The flue pipe is of sufficient size and is properly secured. The flue is equipped with a forced draft fan, integral to the furnace. The chimney furnace flue penetration was not accessible for inspection |
| 6.4 | HEAT DISTRIBUTION SYSTEMS -
Inspect and Describe Comments: Inspected Observable heat distribution ductwork if rectangular, galvanized ductwork that displays no signs of rust, is properly secured and display no signs of rust or physical damage. The entire ductwork system was not visible and could not be inspected. Each room was equipped with an adjustable supply duct, located in the ceiling. The return ducts were directly near the furnace blower unit, below the furnace closet access door and to the south of the furnace closet. |
| 6.5 | HEAT DISTRIBUTION SYSTEMS -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the sufficiency of the return duct system, especially with regards to the seeming lack of a proper supply of combustion air, be evaluated by a licensed and insured HVAC contractor. |
| COOLING EQUIPMENT
TYPE: AIR CONDITIONER UNIT |
COOLING EQUIPMENT ENERGY
SOURCE: ELECTRICITY |
CENTRAL AIR
MANUFACTURER: CARRIER |
| NUMBER OF A/C UNITS: ONE |
| 7.0 | COOLING EQUIPMENT- Inspect
and Describe Comments: Inspected Air conditioning compressor unit could not be observed and was not inspected. |
| 7.1 | NORMAL OPERATING AND SAFETY
CONTROLS - Inspect and Describe Comments: Inspected The air conditioner was controlled by a non-setback type thermostat located on an inside wall. The air conditioner responded properly to normal operating controls. The temperature differential was measured an a return duct proximate to the blower unit and a supply duct distal from the blower unit and found to exceed the recommended 15 degrees. The air conditioner responded properly to normal operating controls. The temperature differential was measured an a return duct proximate to the blower unit and a supply duct distal from the blower unit and found to exceed the recommended 15 degrees. |
| 7.2 | DISTRIBUTION SYSTEMS -
Inspect and Describe Comments: Inspected Air conditioning was distributed by means of rectangular, galvanized steel ductwork that appear to be of adequate size. The duct work was common with the heating system. Refer to the heating section of this report for a more complete description. |
| CEILING MATERIALS: SHEETROCK |
WALL MATERIAL: SHEETROCK |
FLOOR COVERING(S): STONE TILE FLOATING WOOD LAMINATE |
| INTERIOR DOORS: COMPOSITE |
WINDOW TYPES: THERMAL/INSULATED DOUBLE-HUNG |
WINDOW MANUFACTURER: UNKNOWN |
| CABINETRY: MELAMINE |
COUNTERTOP: LAMINATE |
| 8.0 | CEILINGS - Inspect and
Describe Comments: Inspected Ceilings are drywall and display no signs of warp, sag, staining of physical damage. There was a small area, located in the closet of the north bedroom, that displayed some signs of discoloration. Subsequent measurement of the moisture content displayed that the discoloration was probably due to an incomplete paint job rather than staining by moisture from above (Picture 1).
|
| 8.1 | WALLS - Inspect and
Describe Comments: Inspected Walls displayed no signs of warp, stain, sag or physical damage. Drywall joints are smooth and display only minor signs of bulge, consistent with an above average drywall installation. There are minor areas where the baseboard trim is missing, most notably on the bases of the front door stair railing bases on both sides (Picture 1, 2). The bathroom tub surround is tile and appears to be in serviceable condition with no signs of grout loss and is properly caulked to the tun with only minor signs of mildew in the caulk. The east portion of the tub surround is equipped with a small tile covered should. The tile on the vertical and horizontal faces of this shelf have cracks at the corner (Picture 3). The area behind this tile measures as having a high moisture content and there is probably water infiltration into this crack, given the high water environment in a bathroom shower.
|
| 8.2 | WALLS -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the wall trim baseboards, located at the base of the front entry stair railing supports be installed by a licensed and insured trim carpenter. 2) RR - Recommend that, at least, the crack on the corner of the tub surround tile shelf be re-grouted. A better and more lasting solution would be to remove the tile from this area, install the proper concrete type wall board and reset the tile. The tun surround should also have its grout sealed with a silicone grout sealer. Recommend that this area be evaluated by a licensed and insured tiling contractor for repair |
| 8.3 | FLOORS - Inspect and
Describe Comments: Inspected Floors in the majority of the subject unit are floating (not directly secured to the substrate floor) laminate wood flooring. This flooring displays no major signs of cracking, scratches of physical damage. The wooden laminate floor does hare areas that seem to have up and down movement, but this is normal in such a floor type. The padding under the wooden laminate floor is foam and is equipped with the recommended vapor barrier. The major intersections of the laminate flooring to adjacent tile flooring in the kitchen and bathroom areas are missing threshold boards and the interface of the different floor types is evident (Picture 1). The flooring in the kitchen and the bathroom areas is fired clay type, large sized tile. It exhibits no signs of cracking or loose grout. The stepped front door entryway is equipped with an exterior grade tile floor (Picture 2) that is not equipped with bullnose edges and has exposed grout.
|
| 8.4 | FLOORS -
Findings Comments: Inspected, Watch List - Maintenance, Repair or Replace 1) WL - Recommend that the grout in the tile floor be sealed with a silicone sealant to guard against water infiltration to the floor below. 2) RR - Recommend that the places where different floor types (laminate wooden flooring and tile) be equipped with thresholds boards to conceal the underlying floor. Recommend that the threshold be a flat type so as to minimize any trip hazard. Since the underlying floor is a concrete slab, recommend that the threshold be installed with the proper type concrete screws. |
| 8.5 | STEPS, STAIRWAYS, BALCONIES
AND RAILINGS - Inspect and Describe Comments: Inspected The steps leading into the subject unit are equipped with flat railings on each side. These railings are integral to the side seperation walls and are tight, exhibiting to signs of sway or looseness. The stairs leading to the rear entrance are of a similarly type to the front entryway stairs and also exhibit no signs of looseness. |
| 8.6 | COUNTERS AND OF CABINETS -
Inspect and Describe Comments: Inspected Kitchen counters are laminate and display no signs of staining, physical damage of delamination. Kitchen counters are laminate and display no signs of staining, physical damage of delaminating. |
| 8.7 | DOORS (Interior) - Inspect
and Describe Comments: Inspected Interior doors are composite, display no signs of physical damage and hang straight and plumb. They articulate properly with their latches. Door knobs operate and display no signs of physical damage. |
| 8.8 | WINDOWS (Interior) - Inspect
and Describe Comments: Inspected Interior windows are metal, double-paned insulated glass in a double hung configuration. They operate smoothly and articulate properly with their latches. There are cracked glass in some windows throughout home. |
| ATTIC INSULATION: UNKNOWN |
R- VALUE: UNKNOWN |
VAPOR BARRIER: UNKNOWN |
| VENTILATION: UNKNOWN |
EXHAUST FAN TYPES: FAN WITH LIGHT PROPERLY EXAHUSTED TO THE EXTERIOR |
DRYER POWER SOURCE: NONE |
| DRYER VENT: NONE |
| 9.0 | INSULATION AND VAPOR
RETARDERS (in unfinished spaces) - Inspect and Describe Comments: Inspected Unable to inspect, covered by walls. |
| 9.1 | VENTING SYSTEMS (Kitchens,
baths and laundry) - Inspect and Describe Comments: Inspected The bathroom ceiling exhaust fan was properly vented to the exterior. The vent hood on the exterior displays signs of physical damage, but is still functional (Picture 1).
|
| DISHWASHER: NONE |
DISPOSER: NONE |
EXHAUST/RANGE HOOD: NONE |
| RANGE/OVEN: GENERAL ELECTRIC |
BUILT-IN MICROWAVE: NONE |
TRASH COMPACTORS: NONE |
| REFRIGERATOR: GENERAL ELECTRIC |
| 10.0 | RANGES/OVENS/COOKTOPS Comments: Inspected Range and oven operated. Model and serial number was cross-checked against manufacturer and Consumer Product Safety Commission and no posted recalls were found. |
| 10.1 | REFRIGERATOR Comments: Inspected Refrigerator was operating. Model and serial number sere checked against manufacturer and the Consumer Product Safety Commission and no posted recalls were found. |