Prepared For:
Louis Smartbuyer
Property Address:
524 S. Suburban Lane
South Suburbs, IL
_______________________________________________________
William J. Decker Jr. Illinois State License 050.0002240
| Date: 4/10/2004 | Time: 4:30 AM | Report ID: Exp 3 Med |
| Property: 524 S. Suburban Lane South Suburbs, IL |
Customer: Louis Smartbuyer |
Real Estate
Professional: |
Subject property is a 15 year old (1991) split level house with attached 3 car garage. The house sits facing the east and has a central, hipped roof, with two gables crossing it, to the south (over the garage) and to the north. The back is equipped with a wooden deck, a portion of which is screen and metal siding enclosed. It sits on a generally well graded lot and is located near the turnaround section of a cul-du-sac street.
Homes more than 5 years old may have areas that are not current in code requirements. This is not a new home and this home cannot be expected to meet current code standards. While this inspection makes every effort to point out safety issues that may have arisen in the interim, it does not inspect for code but does point out any items that do not meet current safety standards. It is common that homes of any age will have had repairs performed and some repairs may not be in a workmanlike manner. Some areas may appear less than standard. This inspection looks for items that are not functioning as intended. It does not grade the repair. It is sometimes common to see old plumbing or mixed materials. Sometimes water signs in crawlspaces or basements could be years old from a problem that no longer exists. Or, it may still need further attention and repair. Determining this can be difficult in a lived in home. Sometimes homes have signs of damage to wood from wood eating insects. Having this is typical and fairly common. If the home inspection reveals signs of damage you should have a qualified pest control company inspect further for activity and possible hidden damage. Always consider hiring the appropriate expert for any repairs or further inspection.
Comment Key or Definitions
The following definitions of comment descriptions represent this
inspection report. All comments by the inspector should be read and
considered when evaluating this property.
Note:Any recommendations by the inspector
to repair or replace or deal with a significantly
deficient item suggests an evaluation by a licensed
and insured contractor specifically qualified to determine the
condition and safety of the described item, component or system. Please
note that Home Inspectors in the State of Illinois are required to note any
safety hazards, whether they comply with older, obsolete local building codes
or not. Licensed and insured contractors are not. Repairs done
by persons other that licensed and insured contractors carry with them added
liability for the customer. All work
done on the subject property should be accompanied by a copy of all invoices and
warranties, such warranties should be transferable to the new owner and should
include the contractor's license number and a copy of their insurance
certification.
Category Definitions:
Inspected (IN) = The system, component or item was visually observed at a certain time and under certain conditions.Not Inspected (NI)= The system, component or item was not inspected and no representations of whether or not it was functioning are intended. The reason could be that the item was not connected (gas, water, electrical disconnected), obstructed, or not accessible. In any case, the reason that the item, system or component was not inspected is stated in the comments.
Not Present (NP) = This system, component or item is not present in the subject property.
Watch List or Maintenance (WL) =Either the system, component or item needs regular maintenance to remain functioning in a proper manner and those maintenance processes are noted or the item should be watched in anticipation of future problems.Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a licensed and insured contractor. Most of these type of comments describe items that will lead to more serious problems if not addressed. Items, components or systems that can be repaired to satisfactory condition may not need replacement.
Significantly Deficient (SD) = Defined by Illinois State Law as either a) not functioning or b) posing a safety hazard. It should be noted that a large number of significantly deficient items can be addressed at little cost. It is important to remember that The safety of a significantly deficient item is not based upon mere local building codes, which contain 'grandfathering' clauses, or the common practices of tradesmen, but on national and international safety requirements and with the well being of the property and the client in mind.
Please Note: If you have any questions or any thing is unclear, please do not hesitate to contact Decker Home Services and/or your specific inspector. We are happy to answer any of your questions and have a large knowledge base of information and experienced, qualified expert NACHI instructors and inspectors from around the entire country at our disposal. We consider it very important for you to fully and completely understand the condition of the subject property and will do all we can to help you in the process.
| Age Of Home: Over 10 Years (1991) |
Client Is
Present: Yes |
Realtors Present: Buyer's Realtor |
| Weather: Clear |
Temperature: 85 |
Rain in last 3
days: Yes |
| Radon Test: No |
Mold Test: No |
Water Test: No |
9356 N. Keeler Ave. Skokie, IL 60076 |
|
Customer |
|
Property Address |
| 1.1 | FOUNDATION - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the grade around the
entire perimeter of the property be lowered to keep a minimum of 6" (for
brick exterior houses) and 8" for siding or stucco exterior houses) of the
foundation exposed to guard against water infiltration into the
structure. | ||
| 1.7 | ROOF STRUCTURE AND ATTIC - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the water damaged OSB
roof sheathing, located in the garage, northwest corner, be evaluated
and repaired, along with the repair of the downspouts on the western side
of the garage gable roof, proximate to the hip roof side, as needed,
by a licensed and insured roofer. | ||
| 2.1 | WALL CLADDING FLASHING AND TRIM - Findings | |
| Inspected, Watch List - Maintenance | ||
|
1) WL - Recommend that exterior caulking,
where two different exterior surfaces meet, around windows and doors and
where slab porches meet exterior walls, be evaluated and repaired on an
annual basis. This is a regular maintenance item.
2) Wooden siding requires annual evaluation and minor repair of nail pops and flaws. This is a normal maintenance item. | ||
| 2.3 | DOORS (Exterior) - Findings | |
| Inspected, Repair or Replace, Significantly Deficent | ||
|
1) SD) Recommend that the exterior
door between the garage and the living area be equipped with self closing
spring type hinges to guard against infiltration or fire or noxious gasses
from the garage to the living area. This is a safety hazard.
2) RR - Recommend scraping, priming and painting of the door frame for the rear garage door. | ||
| 2.5 | WINDOWS (Exterior) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend exterior wooden window
frames be scrapped, primed and re-painted to avoid further deterioration.
2) RR - Recommend that the junction of the window metal cladding and the exterior brick be caulked to prevent water penetration. | ||
| 2.7 | GARAGE DOOR OPERATORS - Findings | |
| Inspected, Watch List - Maintenance, Repair or Replace | ||
|
1) WL - Adjust resistance auto reverse
feature on south garage door.
2) RR - Recommend that garage doors be scrapped, primed and painted. 3) WL - Recommend evaluation and adjustment of the overhead springs and cables for the garage doors. | ||
| 2.9 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS - Findings | |
| Inspected, Watch List - Maintenance, Repair or Replace | ||
|
1) WL - Cracks between poured slab porches and
exterior walls should be regularly checked and re-caulked, as needed, to
guard against water infiltration.
2) RR - Wooden porches and decks should be supported by the required concrete footings. All deck and porch steps should also be properly supported by concrete footings. Recommend evaluation by a licensed and insured deck contractor. 3) SD - All deck railing ballaster should be spaced no further apart than 3 1/2" to guard against entanglement. This is a safety hazard. 4) SD - Recommend evaluation of the master bedroom balcony by a licensed and insured general contractor. It is the opinion of this inspector that it is not safe for use. | ||
| 2.11 | EAVES, SOFFITS AND FASCIAS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend securing the fascia board on
the gable peak of the south roof. | ||
| 2.13 | VEGETATION, GRADING, DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to their effect on the condition of the building) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the trees growing
directly against the foundation on the south side be removed as a guard
against foundation damage. | ||
| 3.1 | ROOF COVERINGS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend evaluation of damaged area
of roof by a licensed and insured roofer. | ||
| 3.3 | FLASHINGS, SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend evaluation of the roof
flashing to the wooden sided side walls and the chimney cap by a licensed
and insured roofer. | ||
| 3.4 | ROOFING DRAINAGE SYSTEMS - Inspect and Describe | |
| Inspected | ||
|
Roof is drained by means of metal gutters and
downspouts. The metal gutters display no signs of rust and only
minor signs of physical damage. The gutter hangers are spaced more
than the recommended 18" apart (Picture 1).
The downspouts do not extend far enough away from the foundation to be effective in draining water away from the basement. There are two downspouts, located on the garage roof and draining the south side of the upper hip roof, that drain directly on the roof and have already cause signs of past water infiltration (Picture 2, 3). | ||
| 3.5 | ROOFING DRAINAGE SYSTEMS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the downspouts be
extended to release drainage water at least 6' away from the structure's
foundation.
2) RR - Recommend that all downspouts that drain an upper section of roof terminate either into a lower roof section gutter or to the ground, directly as a guard against excessive water buildup and accelerated roof failure. Recommend evaluation and repair by a licensed and insured roofer. | ||
| 4.1 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend evaluation the drain venting
and noises from the master bathroom whirlpool tub by a licensed and
insured plumber. | ||
| 4.3 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend installation of a new
extunction on the 1st floor bathroom showerhead to guard against
showerhead movement. | ||
| 4.8 | SUMP PUMP - Findings | |
| Inspected, Significantly Deficent | ||
|
1) SD - Recommend that all water handling
appliances, including sump pumps and water pressure pumps, be GFCI
protected. This is a safety hazard. Also recommend that all
sump pumps be equipped with battery backup so that their operation is
assured during periods of electrical blackout. SD - Recommend that
all water handling appliances, including sump pumps and water pressure
pumps, be GFCI protected. This is a safety hazard. Also
recommend that all sump pumps be equipped with battery backup so that
their operation is assured during periods of electrical
blackout. | ||
| 5.3 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend evaluation of the added
wiring, located in the laundry utility room to determine the legality of
its use by a licensed and insured electrician. | ||
| 5.5 | CONNECTED DEVICES AND FIXTURES - Findings | |
| Inspected, Significantly Deficent | ||
|
1) RR - Recommend evaluation of the exterior
outlet located near the front door by a licensed and insured
electrician. It was not powered. | ||
| 5.7 | GFCI, AFCI PROTECTION OF RECEPTACLES - Findings | |
| Inspected, Significantly Deficent | ||
|
SD - Recommend GFCI (Ground Fault Circuit
Interrupt) protected outlets, or GFCI circuit breakers for all outlets
that are:
Recommend AFCI (Arc Fault Circuit Interrupt) protected outlets or circuit breakers be used for all branch wiring that services bedroom areas. Recommend that all such installation be done by a licensed and insured electrical contractors and that these outlets and breakers be tested every month by means of the test buttons that they are equipped with. | ||
| 5.9 | SMOKE DETECTORS, CARBON MONOXIDE DETECTORS - Findings | |
| Inspected, Significantly Deficent | ||
|
SD) - Recommend that smoke detectors be
located:
Recommend that carbon monoxide detectors be located in all bedrooms and in any utility room containing a gas fired water heater, furnace or boiler. Recommend that all smoke and carbon monoxide detectors be hard wired to the building's electrical system and be equipped with rechargeable battery backup. | ||
| 6.1 | HEATING EQUIPMENT - Findings | |
| Inspected, Significantly Deficent | ||
|
1) SD - Recommend that the furnace be
evaluated by a licensed and insured HVAC contractor to determine if the
amount of combustion air is sufficient for proper furnace operation.
This is a safety concern.
2) SD - Recommend that the return duct vent, located to the east of the furnace, be covered over to avoid it robbing the furnace of combustion air. | ||
| 6.4 | CHIMNEYS, FLUES AND VENTS - Findings | |
| Inspected, Repair or Replace | ||
|
1) Recommend that the furnace vent flue be
covered with an appropriate vent termination by a licensed and insured
HVAC technician. | ||
| 6.6 | HEAT DISTRIBUTION SYSTEMS - Findings | |
| Inspected, Watch List - Maintenance | ||
|
1) WL - Recommend that the ductwork be cleaned
by a licensed and insured duct cleaning contractor. | ||
| 6.8 | SOLID FUEL HEATING DEVICES - Findings | |
| Inspected, Watch List - Maintenance | ||
|
1) WL - Recommend cleaning of the wood burning
fireplace flue by a licensed and insured chimney sweep.
. | ||
| 6.10 | GAS/LP FIRELOGS, LOG LIGHTERS AND FIREPLACES - Findings | |
| Inspected, Significantly Deficent | ||
|
1) SD - Gas log lighters are not equipped with
automatic gas shut off valves or any safety features that will guard
against gas infiltration into the house. Without any safety feature,
this inspector considers log lighters to be unsafe, especially in houses
with small children. Recommend evaluation by a licensed and insured
fireplace contractor | ||
| 8.3 | FLOORS - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend repair of the cracked floor
tile in the entryway area.
2) RR - Recommend repair of the loose tile in the master bathroom. 3) Recommend re-caulking of the surround of the whirlpool tub to guard against water infiltration. | ||
| 8.6 | COUNTERS AND OF CABINETS - Findings | |
| Inspected, Watch List - Maintenance | ||
|
1) WL - Suggest that replacement of kitchen
countertops may be needed in a 2 to 3 year period due to
delamination. | ||
| 8.8 | DOORS (Interior) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend repair of the door handle
for the 2nd floor hallway bathroom. | ||
| 8.9 | WINDOWS (Interior) - Inspect and Describe | |
| Inspected | ||
|
All windows operated properly and had no signs
of rot or physical damage. | ||
| 9.2 | VENTING SYSTEMS (Kitchens, baths and laundry) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that all bathroom ceiling
fan vents, kitchen vents and laundry dryer vents be vented to the
exterior, directly, to guard against excessive moisture buildup and the
possibility of mold formation. | ||
| 9.4 | VENTILATION, FANS AND THERMOSTATIC CONTROLS (ATTIC) - Findings | |
| Inspected, Repair or Replace | ||
|
1) RR - Recommend that the wasp nests be
removed from the roof vents over the garage. | ||
| 10.0 | DISHWASHER | |
| Inspected, Significantly Deficent | ||
|
Dishwasher was a Tappen. It did not
operate at the time of the inspection. Seller stated that the
Dishwasher "need's servicing".
The dishwasher was not powered by means of a GFCI protected circuit. GFCI outlets are recommended for all water carrying appliances as a safety feature. | ||
| 10.1 | RANGES/OVENS/COOKTOPS | |
| Inspected, Repair or Replace | ||
|
Stove was operated. It is equipped with
electric spark ignition.
Oven is electric and appears to have convection and microwave capabilities, but only the oven function was operated. Suggest client obtain the instruction manual. | ||
| 10.2 | RANGE HOOD | |
| Inspected, Repair or Replace | ||
|
Operated. Needs cleaning of the grease
filter. | ||
| 10.3 | FOOD WASTE DISPOSER | |
| Inspected, Repair or Replace | ||
|
Disposer was operated, but the switch
controlling it appears to have an intermittent flaw, only operating the
disposer sometimes.
Recommend replacement of switch operating the disposer, located to the right of the sink above the counter. | ||
Prepared Using HomeGauge http://www.homegauge.com/ SHGI (c)
2000-2004 : Licensed To Decker Home Services, LLC.
| FOUNDATION: POURED CONCRETE |
FRAMING METHOD: PLATFORM |
FLOOR STRUCTURE: 2 X 8 |
| WALL STRUCTURE: 2 X 4 WOOD |
CEILING STRUCTURE: 2 x 8 WOODEN JOISTS |
BEAMS COLUMNS OR
PIERS: STEEL GIRDER STEEL COLUMNS |
| CEILING STRUCTURE: 2X8 |
ROOF STRUCTURE: STICK-BUILT 2 X 6 RAFTERS LATERAL BRACING OSB SHEATHING |
ROOF-TYPE: HIP COMPLEX CROSSED GABLE |
| ATTIC ACCESS: HATCH |
METHOD USED TO OBSERVE
ATTIC: FROM ENTRY |
CRAWLSPACE ACCESS: NO CRAWLSPACE |
| METHOD USED TO OBSERVE
CRAWLSPACE: NO CRAWLSPACE |
| 1.0 | FOUNDATION - Inspect and
Describe Comments: Inspected Foundation was poured concrete. It extends to a basement area, on the north side of the property, a centrally running footing that runs east to west and a poured concrete slab under the garage area to the south. Foundation displayed only minor signs of cracking and spalling (Picture 1) along the exterior and is not equipped with flashing. There are weep holes located at intervals around the structure in the bottom, vertical butt brick joints. They appear to be generally clean and unclogged. The interior of the foundation, as observed in the furnace and utility rooms, displayed only minor signs of small cracks, consistent with the structure's age, with no bulging or efflorescence. There were no signs of past water infiltration. The sill plate is solid, with no signs of rot and only minor, old staining. The grade around the foundation is above the recommended minimum of 6" below the top at the north (Picture 2) and west (Picture 3, 4) sides of the property. This can lead to water infiltration.
|
| 1.1 | FOUNDATION -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the grade around the entire perimeter of the property be lowered to keep a minimum of 6" (for brick exterior houses) and 8" for siding or stucco exterior houses) of the foundation exposed to guard against water infiltration into the structure. |
| 1.2 | WALLS - Inspect and
Describe Comments: Inspected Structural walls are 2 x 4 studs. Where able to be observed, they are without major staining, twist or physical damage. The sill plates, where able to be observed, was solid, displaying no signs of rot and only minor signs of past water staining. Moisture readings were well within allowable limits (under 6%). There is a small area, located in the northwest corner of the garage, where there is evidence of slight past water staining (Picture 1), but measurements taken for moisture were below 6%. See Roofing and Attic Structure section for more information.
|
| 1.3 | BEAMS, COLUMNS OR PIERS -
Inspect and Describe Comments: Inspected There is a steel girder, running north to south under the center of the structure. It is covered for most of its length, but appears to be free of rust and physical damage. This girder is supported by galvanized metal posts, which, where observable, are properly attached, hang plumb and display no signs of rust or physical damage. The placement of the supporting post at the southern end, in the utility room (Picture 1), appears to be supported on the middle foundation support by metal shims. While this is not an entirely proper construction technique, it appears to be sufficient and displays no signs of shifting, displacement or movement.
|
| 1.4 | FLOORS - Inspect and
Describe Comments: Inspected Structural floor members are 2 x 8 wooden joists, were observed. They display no signs of warp, staining or physical damage, are equipped with limited cross bracing and have only minor notches. The floor joists are covered with 3/4" plywood which was not able to be fully inspected because it was covered, but demonstrates no signs of sag or softness. |
| 1.5 | CEILINGS - Inspect and
Describe Comments: Inspected Ceiling structure, where observed, was 2 x 8 wooden joists that displayed no signs of staining, rot or physical damage. |
| 1.6 | ROOF STRUCTURE AND ATTIC -
Inspect and Describe Comments: Inspected Roof structure was observed from the garage (southern gable) and from the hatch (central hip). The northern gable roof had a cathedral ceiling in most of its area and the hatch to the limited attic in the northern gable was in a closet in the kitchen was obstructed. The attic and roof structure is stick built, with 2 x 6 rafters. The southern gable is equipped with 2 x 4 collar tiles, a 2 x 8 ridge board, 2 x 4 extension from gable end to ridgeboard and 2 x 10 spreaders. The roof is sheathed with OSB and displays no signs of staining with the exception of a small area, located in the northwest corner of the garage where there is evidence of past water infiltration from an improperly installed downspout on the roof above (Picture 1). This is accompanied by signs of old water staining in the adjacent 2 x 4 wall studs and headers. Moisture readings are below 6%. There is some softness in the black area of the roof sheathing. The hip roof is 2 x 6 wooden rafters, supported by 2 x 4 posts and a 2 x 8 ridgeboard (Picture 2) and 2 x 4 collar ties. There are no signs of water staining or physical damage on the OSB roof sheathing.
|
| 1.7 | ROOF STRUCTURE AND ATTIC -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the water damaged OSB roof sheathing, located in the garage, northwest corner, be evaluated and repaired, along with the repair of the downspouts on the western side of the garage gable roof, proximate to the hip roof side, as needed, by a licensed and insured roofer. |
| SIDING STYLE: BEVEL BRICK VERTICAL WOOD SIDING |
SIDING MATERIAL: FULL BRICK METAL VERTICAL WOOD SIDING |
EXTERIOR ENTRY DOORS: FIBERGLASS INSULATED COMPOSITE |
| APPURTENANCE: SIDEWALK DECK POURED CONCRETE SLAB PORCH |
GARAGE DOOR MATERIAL: COMPRESSED BOARD |
GARAGE DOOR TYPE: THREE AUTOMATIC |
| DRIVEWAY: ASPHALT |
| 2.0 | WALL CLADDING FLASHING AND
TRIM - Inspect and Describe Comments: Inspected Exterior walls are a mixture of brick on the lower half of the house, vertically oriented wooden siding on the upper portion and metal siding on the south and west sides of the garage and the north side of the house. The brick exterior displays no significant signs of cracking or mortar loss. There are areas, where the brick meets the metal siding (Picture 1) or the roof soffits (Picture 2), around windows where the caulk is cracked. This is normal and caulk requires annual examination and repair. The wooden siding displays no signs of rot, water staining or physical damage. There area some areas where the siding is slightly separated from the wall (Picture 4) and minor nail pops There is also an area, below the 2nd floor level windows on the front of the property, where the siding appears to be slight twisting under the windows.. There is also an area, located on the southeast corner of the central house area, where some wooden trim needs to be patched and re-painted (Picture 3).
|
| 2.1 | WALL CLADDING FLASHING AND
TRIM - Findings Comments: Inspected, Watch List - Maintenance 1) WL - Recommend that exterior caulking, where two different exterior surfaces meet, around windows and doors and where slab porches meet exterior walls, be evaluated and repaired on an annual basis. This is a regular maintenance item. 2) Wooden siding requires annual evaluation and minor repair of nail pops and flaws. This is a normal maintenance item. |
| 2.2 | DOORS (Exterior) - Inspect
and Describe Comments: Inspected Front exterior doors areas composite, with glass windows double doors. They hangs plumb and articulate properly with their latches. There is some grease like material at the base of the northern door. The side door, which opens into the garage, is composite and also hangs plumb (Picture 1). This door should be equipped with spring hinges so as to close automatically and properly separate the living area from the garage as a guard against fire infiltration. The back door out of the garage (Picture 2) is composite. Its framing displays signs of cracking and should be painted.
|
| 2.3 | DOORS (Exterior) -
Findings Comments: Inspected, Repair or Replace, Significantly Deficent 1) SD) Recommend that the exterior door between the garage and the living area be equipped with self closing spring type hinges to guard against infiltration or fire or noxious gasses from the garage to the living area. This is a safety hazard. 2) RR - Recommend scraping, priming and painting of the door frame for the rear garage door. |
| 2.4 | WINDOWS (Exterior) - Inspect
and Describe Comments: Inspected Exterior windows are a mixture of bow and casements. The exterior frames are wood and display signs of flaking paint (Picture 1). Exterior wooden window frames should be evaluated annually and re-caulked, scraped, primed and painted as needed to guard against deterioration. There are areas where the window frames should be re-caulked. The wooden window frame under the front bow window displays advanced deterioration, but moisture readings are within normal limits and there was no signs of softness in the wood.
|
| 2.5 | WINDOWS (Exterior) -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend exterior wooden window frames be scrapped, primed and re-painted to avoid further deterioration. 2) RR - Recommend that the junction of the window metal cladding and the exterior brick be caulked to prevent water penetration. |
| 2.6 | GARAGE DOOR OPERATORS -
Inspect and Describe Comments: Inspected All three garage doors were tested, with regards to both safety auto-reverse features, and operated properly. The southmost garage door needs some adjustment of the resistance auto reverse feature. The bases of the garage doors are beginning to show wear due to water infiltration (Picture 1). The springs and cables serving the garage doors are not properly adjusted.
|
| 2.7 | GARAGE DOOR OPERATORS -
Findings Comments: Inspected, Watch List - Maintenance, Repair or Replace 1) WL - Adjust resistance auto reverse feature on south garage door. 2) RR - Recommend that garage doors be scrapped, primed and painted. 3) WL - Recommend evaluation and adjustment of the overhead springs and cables for the garage doors. |
| 2.8 | DECKS, BALCONIES, STOOPS,
STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS - Inspect and
Describe Comments: Inspected The rear deck appear to be solid, but the required concrete footings could not be inspected as they may be below grade. The south and north steps on the deck moved and had improper footings (Picture 1, 3). The ballaster railing openings were too wide and pose a safety hazard (Picture 2). Because of the improper footing on the steps, the south railing is loose. The front porch is a poured slab and appears to be in serviceable condition. There is a slight cracking between it an the brick exterior and should be caulked. The master bedroom is equipped with a wooden balcony outside a set of sliding glass doors. This balcony has a significant amount of wood rot in its supporting joists (Picture 4, 5).
|
| 2.9 | DECKS, BALCONIES, STOOPS,
STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS -
Findings Comments: Inspected, Watch List - Maintenance, Repair or Replace 1) WL - Cracks between poured slab porches and exterior walls should be regularly checked and re-caulked, as needed, to guard against water infiltration. 2) RR - Wooden porches and decks should be supported by the required concrete footings. All deck and porch steps should also be properly supported by concrete footings. Recommend evaluation by a licensed and insured deck contractor. 3) SD - All deck railing ballaster should be spaced no further apart than 3 1/2" to guard against entanglement. This is a safety hazard. 4) SD - Recommend evaluation of the master bedroom balcony by a licensed and insured general contractor. It is the opinion of this inspector that it is not safe for use. |
| 2.10 | EAVES, SOFFITS AND FASCIAS -
Inspect and Describe Comments: Inspected Soffits and fascia are wood and display no signs of rot, staining or physical damage. The soffits are equipped with soffits vents for attic ventilation. The fascia board, located at the peak of the south gable (Picture 1) is slightly misaligned and should be re-nailed to guard against water infiltration.
|
| 2.11 | EAVES, SOFFITS AND FASCIAS -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend securing the fascia board on the gable peak of the south roof. |
| 2.12 | VEGETATION, GRADING,
DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to
their effect on the condition of the building) - Inspect and
Describe Comments: Inspected Draining and slope of grade are, in general, good. There are areas, to the north and west sides, where grade is overly high and should be re-graded. There are some small trees that are growing right up against the foundation on the south side (Picture 1) that should be removed as a guard against foundation damage.
|
| 2.13 | VEGETATION, GRADING,
DRAINAGE, DRIVEWAYS, PATIOS, WALKWAYS AND RETAINING WALLS (With respect to
their effect on the condition of the building) - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the trees growing directly against the foundation on the south side be removed as a guard against foundation damage. |
| ROOF COVERING: 3-TAB FIBERGLASS DIMENTIONAL ASPHALT/ FIBERGLASS |
VIEWED ROOF COVERING
FROM: GROUND LADDER WALKED ROOF |
SKY LIGHT (S): TWO |
| CHIMNEY (exterior): BRICK WITH CLAY TILE LINER |
| 3.0 | ROOF COVERINGS - Inspect and
Describe Comments: Inspected Roof covering is 3 tab asphalt impregnated fiberglass. The roof covering is in good shape but has a moderate amount of granule loss, especially between the shingle gutters (Picture 1). There is a small area, located over the garage, where one shingle appears to be damaged (Picture 2), apparently from impact with an object.
|
| 3.1 | ROOF COVERINGS -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend evaluation of damaged area of roof by a licensed and insured roofer. |
| 3.2 | FLASHINGS, SKYLIGHTS,
CHIMNEYS AND ROOF PENETRATIONS - Inspect and Describe Comments: Inspected The roof flashings are metal and properly extend under the siding, although the siding is not cut back to the recommended 2" above the roof surface (Picture 1). There are only minor signs of active water wicking due to this condition. The chimney, skylights (Picture 3) and vents are properly flashed and there was no sign of water infiltration on the interior. The chimney is not equipped with a rain cap or a pest screen and it's chimney cap is inadequate and cracked (Picture 2).
|
| 3.3 | FLASHINGS, SKYLIGHTS,
CHIMNEYS AND ROOF PENETRATIONS - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend evaluation of the roof flashing to the wooden sided side walls and the chimney cap by a licensed and insured roofer. |
| 3.4 | ROOFING DRAINAGE SYSTEMS -
Inspect and Describe Comments: Inspected Roof is drained by means of metal gutters and downspouts. The metal gutters display no signs of rust and only minor signs of physical damage. The gutter hangers are spaced more than the recommended 18" apart (Picture 1). The downspouts do not extend far enough away from the foundation to be effective in draining water away from the basement. There are two downspouts, located on the garage roof and draining the south side of the upper hip roof, that drain directly on the roof and have already cause signs of past water infiltration (Picture 2, 3).
|
| 3.5 | ROOFING DRAINAGE SYSTEMS -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend that the downspouts be extended to release drainage water at least 6' away from the structure's foundation. 2) RR - Recommend that all downspouts that drain an upper section of roof terminate either into a lower roof section gutter or to the ground, directly as a guard against excessive water buildup and accelerated roof failure. Recommend evaluation and repair by a licensed and insured roofer. |
| WATER SOURCE: PUBLIC |
WATER FILTERS: NONE |
PLUMBING SUPPLY: COPPER |
| PLUMBING
DISTRIBUTION: COPPER |
WASHER DRAIN SIZE: 2" DIAMETER |
PLUMBING WASTE: PVC |
| WATER HEATER POWER
SOURCE: GAS |
CAPACITY: 75 GALLON |
MANUFACTURER: RHEEM |
| 4.0 | INTERIOR DRAIN, WASTE AND
VENT SYSTEMS - Inspect and Describe Comments: Inspected Interior drain waste and vent systems are PVC piping and appear to be serviceable. All sinks drained properly. The whirlpool tub in the master bedroom made some excessive gurgling noises on drainage and this may be an indication of inadequate venting. |
| 4.1 | INTERIOR DRAIN, WASTE AND
VENT SYSTEMS - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend evaluation the drain venting and noises from the master bathroom whirlpool tub by a licensed and insured plumber. |
| 4.2 | INTERIOR WATER SUPPLY AND
DISTRIBUTION SYSTEMS AND FIXTURES - Inspect and Describe Comments: Inspected Interior supply pipes are copper and display no signs of corrosion or physical damage. Water supply and pressure was adequate. The Whirlpool tun was operated and displayed no signs of pipe mildew. The whirlpool tun did exhibit gurgling during drainage as detailed in the Drainage Section. All plumbing fixtures operated properly and appeared sound. All toilets were properly seated and displayed no signs of leakage and drained properly. The shower head, located in the hallway bathroom on the 2nd floor was not properly secured in the wall and moves (Picture 1).
|
| 4.3 | INTERIOR WATER SUPPLY AND
DISTRIBUTION SYSTEMS AND FIXTURES - Findings Comments: Inspected, Repair or Replace 1) RR - Recommend installation of a new extunction on the 1st floor bathroom showerhead to guard against showerhead movement. |
| 4.4 | HOT WATER SYSTEMS, CONTROLS,
CHIMNEYS, FLUES AND VENTS - Inspect and Describe Comments: Inspected Hot waster heater was a 75 gallon gas unit. It was observed through a heating cycle and had the proper colored flame. It was draft vented to a dedicated, insulated steel flue pipe. TPR drainage pipe was proper. No gas leaks detected. |
| 4.5 | MAIN WATER AND FUEL SHUT-OFF
DEVICES (Describe location) - Findings Comments: Inspected Main water shut off is located in the furnace utility room on the east wall of the northern basement area (Picture 1). Main fuel shut off is at the meter, located at the east corner of the north wall (Picture 2).
|
| 4.6 | FUEL STORAGE AND DISTRIBUTION
SYSTEMS - Findings Comments: Inspected Gas was distributed by means of the proper black pipe. |
| 4.7 | SUMP PUMP - Inspect and
Describe Comments: Inspected There is a drainage sump pump, located at the northwest corner of the basement. It operated properly. There is an ejector sump, located in the west portion of the laundry utility room (Picture 1). It was sealed and could not be tested, although it did go on by itself when the toilet was used.
|
| 4.8 | SUMP PUMP -
Findings Comments: Inspected, Significantly Deficent 1) SD - Recommend that all water handling appliances, including sump pumps and water pressure pumps, be GFCI protected. This is a safety hazard. Also recommend that all sump pumps be equipped with battery backup so that their operation is assured during periods of electrical blackout. SD - Recommend that all water handling appliances, including sump pumps and water pressure pumps, be GFCI protected. This is a safety hazard. Also recommend that all sump pumps be equipped with battery backup so that their operation is assured during periods of electrical blackout. |
| ELECTRICAL SERVICE
CONDUCTORS: BELOW GROUND (Lateral Drop) |
METER CAPACITY: 200 AMPS |
PANEL CAPACITY: 200 AMP |
| PANEL TYPE: CIRCUIT BREAKERS |
ELEC. PANEL
MANUFACTURER: GENERAL ELECTRIC |
BRANCH WIRE 15 and 20
AMP: COPPER |
| WIRING METHODS: ROMEX CONDUIT |
| 5.0 | SERVICE DROP AND ENTRANCE,
CONDUCTORS - Inspect and Describe Comments: Inspected Service is by lateral drop with the meter located on the west side of the northern end of the property (Picture 1). Meter is rated for 200 amp service. No signs of rust of physical damage.
|
| 5.1 | SERVICE AND GROUNDING
EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS - Inspect
and Describe Comments: Inspected Main equipment service panel is located behind a wall door on the western side of the north basement area. The main breaker is rated for 200 amps. The panel appears clean and without signs of rust, although there are some small spider webs inside. Grounding means is underground and not inspected, but the grounding ware is properly bonded to the panel and the neutral buss in the panel. |
| 5.2 | BRANCH CIRCUIT CONDUCTORS,
OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE -
Inspect and Describe Comments: Inspected All branch conductors are solid copper and of the proper size and gauge. The wiring is neat and the wires display no signs of discoloration or melting of insulation. There are two double ganged, 240 volt breakers serving the air conditioning compressor and the electric oven. All wiring distributed from the main panel are in conduit. There are signs of later electrical additions which was done using unarmored flexible cable (Romex type) which displays no signs of damage and is properly secured. It is unsure whether this type of wiring is allowed. |
| 5.3 | BRANCH CIRCUIT CONDUCTORS,
OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE -
Findings Comments: Inspected, Repair or Replace 1) RR - Recommend evaluation of the added wiring, located in the laundry utility room to determine the legality of its use by a licensed and insured electrician. |
| 5.4 | CONNECTED DEVICES AND
FIXTURES - Inspect and Describe Comments: Inspected All switches and outlets tested properly for polarity and grounding. All switches tested properly. The exterior outlet, located near the front door was not powered. The switch serving the in sink disposer operates intermittently and should be replaced (Picture 1).
|
| 5.5 | CONNECTED DEVICES AND
FIXTURES - Findings Comments: Inspected, Significantly Deficent 1) RR - Recommend evaluation of the exterior outlet located near the front door by a licensed and insured electrician. It was not powered. |
| 5.6 | GFCI, AFCI PROTECTION OF
RECEPTACLES - Inspect and Describe Comments: Inspected The garage was equipped with a GFCI outlet that operated properly. The exterior outlet, located at the rear of the property operated properly. No GFCI or AFCI outlets were observed in the living area of of the property, nor were their any GFCI or AFCI breakers in the main service equipment panel. Was not able to inspect the outlet serving the whirlpool tub in the master bathroom because the access panel was not accessible. |
| 5.7 | GFCI, AFCI PROTECTION OF
RECEPTACLES - Findings Comments: Inspected, Significantly Deficent SD - Recommend GFCI (Ground Fault Circuit Interrupt) protected outlets, or GFCI circuit breakers for all outlets that are:
Recommend AFCI (Arc Fault Circuit Interrupt) protected outlets or circuit breakers be used for all branch wiring that services bedroom areas. Recommend that all such installation be done by a licensed and insured electrical contractors and that these outlets and breakers be tested every month by means of the test buttons that they are equipped with. |
| 5.8 | SMOKE DETECTORS, CARBON
MONOXIDE DETECTORS - Inspect and Describe Comments: Inspected Smoke detectors were located in the hallway outside the 2nd floor bedrooms and the basement bedroom. |
| 5.9 | SMOKE DETECTORS, CARBON
MONOXIDE DETECTORS - Findings Comments: Inspected, Significantly Deficent SD) - Recommend that smoke detectors be located:
Recommend that carbon monoxide detectors be located in all bedrooms and in any utility room containing a gas fired water heater, furnace or boiler. Recommend that all smoke and carbon monoxide detectors be hard wired to the building's electrical system and be equipped with rechargeable battery backup. |
| HEAT TYPE: FORCED AIR FORCED DRAFT |
FURNACE EFFICENCY: HIGH EFFICENCY INSUFFICIENT COMBUSTION AIR |
ENERGY SOURCE: NATURAL GAS |
| NUMBER OF HEAT SYSTEMS (excluding
fireplaces): ONE |
HEAT SYSTEM BRAND: ULTRA |
DUCTWORK: RECTANGULAR GALVANIZED STEEL |
| FILTER TYPE: ELECTRONIC AIR CLEANER |
TYPES OF FIREPLACES: GAS/LP LOG STARTER |
OPERABLE FIREPLACES: ONE |
| NUMBER OF WOODSTOVES: NONE |
| 6.0 | HEATING EQUIPMENT - Inspect
and Describe Comments: Inspected Furnace was located in the basement utility room on the east wall. It was a forced draft, high efficiency model manufactured in 1989. The flame was observed during a heating cycle and has an excessive yellow case. This could be due to insufficient combustion air and/or the furnace not being regularly maintained. High efficiency furnaces should be inspected and maintained annually. There was a vent located in the rerun air duct to the east of the furnace that is probably robbing the furnace of combustion air (Picture 1).
|
| 6.1 | HEATING EQUIPMENT -
Findings Comments: Inspected, Significantly Deficent 1) SD - Recommend that the furnace be evaluated by a licensed and insured HVAC contractor to determine if the amount of combustion air is sufficient for proper furnace operation. This is a safety concern. 2) SD - Recommend that the return duct vent, located to the east of the furnace, be covered over to avoid it robbing the furnace of combustion air. |
| 6.2 | NORMAL OPERATING AND SAFETY
CONTROLS - Inspect and Describe Comments: Inspected The furnace responded properly to the thermostat controls, located on an inside wall in the dining room on the 1st floor, located on the north end of the structure. The main electrical shut off switch for the furnace blower is located on the west side of the furnace. |
| 6.3 | CHIMNEYS, FLUES AND VENTS -
Inspect and Describe Comments: Inspected The furnace is vented by means of PVC vent pipe to the side of the property, at the front to the north of the front door. The vent termination is equipped with a metal cover that is damaged (Picture 1).
|
| 6.4 | CHIMNEYS, FLUES AND VENTS -
Findings Comments: Inspected, Repair or Replace 1) Recommend that the furnace vent flue be covered with an appropriate vent termination by a licensed and insured HVAC technician. |
| 6.5 | HEAT DISTRIBUTION SYSTEMS -
Inspect and Describe Comments: Inspected Both heat and air conditioning is distributed by means of rectangular and round galvanized steel ductwork that is of sufficient size for both heating and air conditioning service. It displays only minor signs of rust and ho physical damage. Closer examination shows that the ductwork has small amounts of debris (Picture 1).
|
| 6.6 | HEAT DISTRIBUTION SYSTEMS -
Findings Comments: Inspected, Watch List - Maintenance 1) WL - Recommend that the ductwork be cleaned by a licensed and insured duct cleaning contractor. |
| 6.7 | SOLID FUEL HEATING DEVICES -
Inspect and Describe Comments: Inspected Property is equipped with a single wood burning fireplace located at the southwest corner of the lower level family room. The fireplace is equipped with a gas log lighter. The damper operated properly and the flue has minor soot buildup. |
| 6.8 | SOLID FUEL HEATING DEVICES -
Findings Comments: Inspected, Watch List - Maintenance 1) WL - Recommend cleaning of the wood burning fireplace flue by a licensed and insured chimney sweep. . |
| 6.9 | GAS/LP FIRELOGS, LOG LIGHTERS
AND FIREPLACES - Inspect and Describe Comments: Inspected Fireplace was equipped with a gas 'log lighter'. It's gas shut off valve was located to the left of the fireplace on the wall base. |
| 6.10 | GAS/LP FIRELOGS, LOG LIGHTERS
AND FIREPLACES - Findings Comments: Inspected, Significantly Deficent 1) SD - Gas log lighters are not equipped with automatic gas shut off valves or any safety features that will guard against gas infiltration into the house. Without any safety feature, this inspector considers log lighters to be unsafe, especially in houses with small children. Recommend evaluation by a licensed and insured fireplace contractor |
| COOLING EQUIPMENT
TYPE: AIR CONDITIONER UNIT |
COOLING EQUIPMENT ENERGY
SOURCE: ELECTRICITY |
CENTRAL AIR
MANUFACTURER: CARRIER |
| NUMBER OF A/C UNITS: ONE |
| 7.0 | COOLING EQUIPMENT- Inspect
and Describe Comments: Inspected The air conditioner compressor was located at the northwest corner of the property. It was manufactured in 1989. It displayed no signs of rust or physical damage. |
| 7.1 | NORMAL OPERATING AND SAFETY
CONTROLS - Inspect and Describe Comments: Inspected Air conditioner operated properly to normal operating controls. The air conditioner electrical disconnect is located on the side of the house, directly behind the compressor unit. |
| 7.2 | DISTRIBUTION SYSTEMS -
Inspect and Describe Comments: Inspected See Heating section for details of ductwork. |
| CEILING MATERIALS: SHEETROCK |
WALL MATERIAL: SHEETROCK |
FLOOR COVERING(S): CARPET HARDWOOD T&G TILE |
| INTERIOR DOORS: HOLLOW CORE WOOD |
WINDOW TYPES: CASEMENT WOOD |
WINDOW MANUFACTURER: UNKNOWN |
| CABINETRY: WOOD |
COUNTERTOP: LAMINATE |
| 8.0 | CEILINGS - Inspect and
Describe Comments: Inspected Ceilings were without signs of water staining, sag or drywall joint swell. |
| 8.1 | WALLS - Inspect and
Describe Comments: Inspected Walls were without signs of warp, sag, cracking and stains. |
| 8.2 | FLOORS - Inspect and
Describe Comments: Inspected Floors were hardwood, tongue and groove (with intricate inlays) and tile. There was minor signs of cracking the the tile floor in the entryway. The remainder of the floors were covered with carpet and not observable. There is also an area, located on the south side of the whirlpool tub that should be sealed with caulk. There is a loose tile, located on the steps leading to the whirlpool tun in the master bedroom (Picture 1).
|