| Decker Home Services |
Water intrusion consultation for wet buildings and mold problems.
The
Chicago area housing market has a growing problem that has occurred over the past couple of
years. Houses and condominium buildings have been experiencing a large
amount of water intrusion. Sometimes this water is the result of a leaky
roof, always the first suspect, but more commonly water is entering the
building through the exterior masonry walls and stone trim. The picture,
at left, is a fine example. Notice the powdery white smears on the brick.
This phenomenon is called efflorescence. It forms when water that has been
absorbed by the brick and stone (both are porous) and wicks outward. As the
water travels, it dissolves some of the lime from the mortar. When the
moisture reaches the outside surface and evaporates, it leaves these lime
deposits behind. Efflorescence, in itself, is not a problem and can easily
be removed (with a vinegar and water solution) but it is a sign of a larger
underlying problem. The masonry walls are not properly constructed, sealed and flashed
so
excessive amounts of water are entering the building envelope. Water intrusion leads
to deterioration of the masonry, rotting of the wooden windows frames and floor
joists, stained drywall and promotes mold formation.
Our company has become (much to our surprise) this region's experts on water intrusion problems, unfortunately, because these problems are becoming more common. Here are some of the causes we have found:
|
Improper
installation of coping stones: Buildings with flat roofs are built
with parapet walls (around the sides of the roof).
| |
|
Improperly installed or missing flashing above windows and doors: Exterior wall openings (for windows and doors) are built using a lintel. This is an angled piece of steel that rests on the sides of the openings and supports the brick or stone over the opening (below, left). The area behind the lintel will accumulate moisture and it will flow down to the lintel. The lintel must have flashing (usually, a plastic membrane) that runs between |
the
lintel and overlying brick.
This membrane will direct the water out, between the brick
and the lintel so that it will not drip down through the top of the window or
door frame. Many times, the builder does not properly install this
flashing. Another overlooked construction detail is the fact that the
lintel / brick space should be open. Many uninformed masons will grout
(mortar) or caulk this gap closed. If this gap is sealed shut, the accumulated
water will flow outwards and run down the sides of the openings (above, right/
Note the efflorescence on the sides of the door and window). Newer construction techniques also call for "weep
wicks", small pieces of rope that hang out of the lintel space or at the base or
sides of the walls. These weep wicks suck water out of the wall and wick it to
the air, much like a paper towel will soak up water. Too often, these wicks are
missing, improperly installed or not the recommended nylon or polypropylene, but
just cotton clothesline. Cotton weep wicks will rot and deteriorate in a
couple of years.
|
Unsuitable
materials and improper construction detail: There are always new
building materials coming on the market. Usually, these materials are
superior (and less expensive) than the old
|
We have a great deal of experience evaluating these types of problems and can provide an un-biased inspection using the latest technology. Our inspection report will provide you with quantitative information on the condition of the building and give suggestions on how the water intrusion problem can be solved. We also will be able to guide you to a number of forensic contractors who can properly, and finally, fix the condition.